Letronic e.K. is official distributor of Lapp Cable.
ÖLFLEX® VFD 2XL 4/4C
Supplier-ID: 700706
Description
Connecting cable between frequency converter and motor, For fixed installation and applications with occasional movements, Plant construction, Industrial machinery and machine tools, Areas at risk of explosion (class 1 division 2) in accordance with NEC articles 336, 501, Reduced insulation wall thickness, therefore a space-saving installation, UL TC-ER and c(UL) CIC/TC approval, Multi-standard certification reduces part varieties and saves costs, Cost-saving, easy installation due to omission of closed cable systems (suitable for open wiring), Longer cable connection possible between converter and drive due to low capacitance design, Fine-wire, tin-plated copper conductor, Core insulation: XLPE, Screening braid made of tin-plated copper wires, Outer sheath: Specially designed thermoplastic elastomer (TPE), black, Aluminium-coated foil, UL TC-ER (exposed run) according to UL 1277, Flexible motor supply cable according to UL, Class 1 division 2 in accordance with NEC art. 336, 501, c(UL) CIC/TC FT4; cRU AWM I/II A/B FT4, CE (50V - 1kV), Oil-resistant according to UL OIL RES I & II, Flame-retardant according to CSA FT4 UL Vertical-Tray Flame Test, Sunlight resistant (UV-resistant); direct burial (can be buried in the ground according to US standards), 90°C Wet or Dry; -40°C Cold Bend; -25°C Cold Impact,
| Specification | Value |
|---|---|
| Werkstoff der Aderisolation | Polyolefine |
| Flammwidrig | nach EN 60332-1-2 |
| Nennspannung U | 1 |
| Mantel-Farbe | schwarz |
| Mantelmaterial | sonstige |
| Schutzleiter | Yes |
| Zul. Kabelaußentemperatur bei Montage/Handling | -25 - 90 |
| Zul. Kabelaußentemperatur nach Montage ohne Erschütterung | -40 - 90 |
| Torsionsschutz | No |
| Tragorgan | ohne |
| Leitungs-Breite ca. | - |
| Leitungs-Höhe ca. | - |
| Außendurchmesser ca. | 29.4 |
| Ölbeständig nach EN 60811-404 | No |
| Min. zulässiger Biegeradius, flexibler Einsatz/freie Bewegung | 441 |
| Min. zulässiger Biegeradius, stationärer Einsatz/fest verlegt | 220.5 |
| Min. zulässiger Biegeradius, flexibler Einsatz mit Zwangsführung | - |
| Spezifizierung Aderisolation | sonstige |
| Spezifizierung Mantelmaterial | sonstige |
| Ausführung | rund |
| Hauptader-Zahl | 4 |
| Hauptleiter-Nennquerschnitt | 25 |
| Hauptader-Kennzeichnung | Ziffern |
| Hilfsleiter-Nennquerschnitt | - |
| Hilfsader-Zahl | - |
| AWG-Größe Hauptleiter | 4 |
| Hauptleiter-Nennquerschnitt (AWG) | 4 |
| Hilfsleiter-Nennquerschnitt (AWG) | - |