Connection cable for use in electronics and in measurement, control, regulation and signal applications, This cable is also used as an impulse and data transmission cable, JE-LiYCY...BD has also proved itself to be an excellent connection cable for telephone systems, e.g. call and intercom systems, For fixed installation on and under plaster, in dry and damp rooms, If installing outside, this cable should be installed under plaster only, Can be used for Maxi TERMI-POINT® wiring, Overall shield minimises electrical interference, Decoupling of circuits by means of twisted-pair (TP) design (crosstalk effects), 7-wire strand made of bare copper wires, Core insulation made of PVC, 2 cores twisted into a pair, and 4 pairs into a bundle (for 2 x 2 x 0.5 as star quad), Bundles twisted in layers, foil wrapping, screening braid made of tin-plated copper wires, Outer sheath made of PVC Outer sheath colour: sky blue (RAL 5015), In accordance with DIN VDE 0815 type JE-LiYCY...BD, JE-LiYCY...BD EB: For intrinsically safe circuits (ignition protection type i - intrinsic safety) according to IEC 60079-14:2013 / EN 60079-14:2014 / VDE 0165-1:2014, section 16.2.2, The 2-pair version (2 x 2 x 0.5) is twisted into a star quad, Flame-retardant according to IEC 60332-1-2,
Specification | Value |
---|---|
Leiter-Nennquerschnitt | 0.5 |
Werkstoff der Aderisolation | Polyvinylchlorid (PVC) |
Ader-Kennzeichnung | Farbe + Ringe |
Flammwidrig | nach IEC 60332-1-2 |
Verseilelement | Paare |
Mantel-Farbe | blau |
Schirm über Verseilelement | ohne |
Schirm über Verseilung | Geflecht |
Mantelmaterial | Polyvinylchlorid (PVC) |
Zul. Kabelaußentemperatur bei Montage/Handling | -5 - 50 |
Zul. Kabelaußentemperatur nach Montage ohne Erschütterung | -40 - 70 |
Ader-Zahl | 80 |
Außendurchmesser ca. | 21.7 |
Raucharm nach EN 61034-2 | No |
Halogenfrei nach EN 60754-1/2 | No |
Ölbeständig nach EN 60811-404 | No |
Min. zulässiger Biegeradius, flexibler Einsatz/freie Bewegung | 325.5 |
Min. zulässiger Biegeradius, stationärer Einsatz/fest verlegt | 108.5 |
Spezifizierung Aderisolation | sonstige |
Spezifizierung Mantelmaterial | sonstige |
UV-beständig | No |
Bewehrung | No |
Funktionserhalt | nein |
Schutzmantel | nein |
AWG-Querschnitt | 22 |
Halogenfrei nach IEC 60754-2 | No |
Isolationserhalt nach IEC 60331 | No |
Raucharm nach IEC 61034-2 | No |
Verseilung | |
Ölbeständig nach IEC 60811-404 | No |
Leiter-Oberfläche | blank |
Kabel längswasserdicht | No |
Kabel querwasserdicht | No |