JE-Y(ST)Y...BD EB 32X2X0,8
Supplier-ID: 0034126
Description
Connection cable for fixed installation in industrial control systems, as required in measurement, control, regulation, signalling and data applications, Industrial electronics, For fixed installation on and under plaster, in dry and damp rooms, If installing outside, this cable should be installed under plaster only, Perfect for cost-effective installation, e.g. connections with insulation displacement technology (IDC)., Static shield made of aluminium-laminated plastic film with drain wire minimises the interference of high frequency, electromagnetic fields, Decoupling of circuits by means of twisted-pair (TP) design (crosstalk effects), Solid bare copper conductor, Core insulation made of PVC, 2 cores twisted into a pair, and 4 pairs into a bundle (for 2 x 2 x 0.8 as star quad), Foil wrapping, static shielding made of aluminium-laminated plastic film with copper drain wire, Outer sheath made of PVC Outer sheath colour: sky blue (RAL 5015), In accordance with DIN VDE 0815 type JE-Y(ST)Y...BD, Flame-retardant according to IEC 60332-1-2, The 2-pair version (2 x 2 x 0.8) is twisted into a star quad, JE-Y(ST)Y...BD EB: For intrinsically safe circuits (ignition protection type i - intrinsic safety) according to IEC 60079-14:2013 / EN 60079-14:2014 / VDE 0165-1:2014, section 16.2.2,
Specification | Value |
---|---|
Werkstoff der Aderisolation | Polyvinylchlorid (PVC) |
Ader-Kennzeichnung | Farbe + Ringe |
Flammwidrig | nach IEC 60332-1-2 |
Verseilelement | Paare |
Mantel-Farbe | blau |
Schirm über Verseilelement | ohne |
Schirm über Verseilung | Folie |
Mantelmaterial | Polyvinylchlorid (PVC) |
Zul. Kabelaußentemperatur bei Montage/Handling | -5 - 50 |
Zul. Kabelaußentemperatur nach Montage ohne Erschütterung | -40 - 70 |
Ader-Zahl | 64 |
Außendurchmesser ca. | 20 |
Raucharm nach EN 61034-2 | No |
Halogenfrei nach EN 60754-1/2 | No |
Ölbeständig nach EN 60811-404 | No |
Min. zulässiger Biegeradius, stationärer Einsatz/fest verlegt | 120 |
Spezifizierung Aderisolation | sonstige |
Spezifizierung Mantelmaterial | sonstige |
UV-beständig | No |
Bewehrung | No |
Funktionserhalt | nein |
Leiter-Durchmesser | 0.8 |
Schutzmantel | nein |
Halogenfrei nach IEC 60754-2 | No |
Isolationserhalt nach IEC 60331 | No |
Raucharm nach IEC 61034-2 | No |
Verseilung | |
Ölbeständig nach IEC 60811-404 | No |
Leiter-Oberfläche | blank |
Kabel längswasserdicht | No |
Kabel querwasserdicht | No |