Power cord SO, SOW, SOOW 600V UL62 and UL/cUL 90°C AWG4

 

Construction 

  • Conductors:                Flexible stranded bare copper or tin-coated copper in acc.
                               with ASTM B-174 and UL62
  • Seperator:                 Paper tape as needed
  • Insulation:                EPR compound Class 3 comply with Table 8 of UL 62
  • Colour code:               ICEA S-58-679, Method 1, Tab. 1
                               2/C black, white
                               3/C black, white, green
                               4/C black, white, green, red
                               5/C black, white, green, red, orange 
                               Number Colour Tracer 
                               of core            of core             of core 
                               1 black            8 red black         15 blue white 
                               2 white            9 green black       16 black red
                               3 red             10 orange black      17 white red
                               4 green           11 blue black        18 orange red
                               5 orange          12 black white       19 blue red
                               6 blue            13 red white         20 red green
                               7 white black     14 green white       21 orange green 
  • cabling:                   Insulated conductors are assembled round together (Integral Version)
  • Seperator:                 Paper or polyester tape under jacket (above 5 cores cables)
  • outer jacket:              CPE compound Class 1.4 comply to table 11 of UL62
  • Colour of outer jacket:    black, other colors available on request 
  • Marking:                   printing according to UL62 E501490

 

Technical specification

  • operating voltage UL:      600 V
  • Temperature range:         -40°C bis +90°C
                              

 

Applications 

  • excellent flexibility, resistant to oil, solvents, ozone, sunlight and water
  • good weather resistance
  • Minimum bending radius: 6 x total diameter of the cable

 

 


Number of cores Conductor strand nom. insulation thickn. mm nom. jacket thickn. mm overall diameter mm article #
2 165/0,396 1,52 3,56 26,9 2180204010
3 165/0,396 1,52 3,56 28,7 2180304010
4 165/0,396 1,52 3,94 31,8 2180404010
5 165/0,396 1,52 3,94 33,2 2180504010
  • Weitere Anfertigungen auf Anfrage
  • Alle Angaben ohne Gewähr
  • Sollten Sie Fragen zu diesem Produkt haben, können Sie uns gerne telefonisch oder über unser Kontaktformular erreichen.