Silicone UL 3580

Construction

 

  • Conductor:              flexible tin coated annealed copper wires
  • Insulation:             silicone rubber
  • Marking:                RU AWM STYLE 3580 150° 1kV

 

Technical Data

 

  • Rated voltage Uo/U:                          acc. to UL, CSA 0 1000 V r.m.s.
  • Test voltage:                                300 V acc. to UL 758
  • Operating voltage:                           600 V
  • Temperature:                                 -60°C to +150°C
    (acc. to UL 758; CSA C22.2 No. 210)   
  • max. temperature in case of short circuit:   350°C on the conductor (max duration 5 seconds) 
  • minimum installation & handling temperature: -25°C
  • minimum bending radius:                      4 x outer diameter
  • max laying stress during installation:       50 N/qmm

 

Characteristics 

 

  • As Motor Leads or Internal Wiring of Appliances or Electronic Equipment where not subjected to mechanical abuse.
  • Flame behaviour Reduced flame spread according to:
    FT-2 Horizontal Flame Test according to UL 758, Sec. 44 / CSA C22.2 No. 210, Clause 11.8(b)
    IEC 60332-1-2 : Tests on electric and optical fibre cables under fire conditions -
    Part 1-2: Test for vertical flame propagation for a single insulated wire or cable -
    Procedure for 1 kW pre-mixed flame
  • Halogen free according to:
    - IEC 60754-1: Test on gases evolved during combustion of materials from cables -
    Part 1: Determination of the halogen acid gas content
    - IEC 60754-2: Test on gases evolved during combustion of materials from cables -
    Part 2: Determination of acidity (by pH measurement) and conductivity
    - IEC 61034-1/2 : Measurement of smoke density of cables burning under defined conditions -
    Part 1: Test apparatus /Part 2: Test procedure and requirements
  • EU Environmental Regulations Compliance:
    - Reach Regulation 1907/2006/EC compliant.
    - RoHS Directive 2002/95/EC compliant.
    - WEEE Directive 2002/96/EC compliant.
     

qmm AWG Construction Insulation thicknes outer Ø mm max cond. resistance at 20°C Ohms/km indicative weight Kg/km articlenumber
0,5 21 14 x 0,2 1,14 mm 3,3 +/- 0,1 40,1 16 7809056010
0,75 19 21 x 0,2 1,14 mm 3,5 +/- 0,1 26,7 19 7809076010
1 18 28 x 0,2 1,14 mm 3,6 +/- 0,1 20,0 22 7809016010
1,5 16 28 x 025 1,14 mm 3,9 +/- 0,1 13,7 28 7809156010
2,5 14 47 x 0,25 1,14 mm 4,5 +/- 0,1 8,21 39 7809256010
4 12 54 x 0,3 1,14 mm 4,9 +/- 0,1 5,09 53 7809406010
6 10 80 x 0,3 1,14 mm 5,4 +/- 0,2 3,39 72 7809606010
10 8 77 x 0,4 1,52 mm 7,5 +/- 0,2 1,95 135 7809106010
16 6 119 x 0,4 1,52 mm 8,5 +/- 0,2 1,24 190 7809161010
25 4 182 x 0,4 1,52 mm 9,7 +/- 0,2 0,795 270 7809256010
35 2 260 x 0,4 1,52 mm 11,0 +/- 0,3 0,565 370 7809356010
50 1 364 x 0,4 2,03 mm 13,4 +/- 0,3 0,393 540 7809506010
70 2/0 336 x 0,5 2,03 mm 15,2 +/- 0,3 0,277 750 7809706010
95 3/0 456 x 0,5 2,03 mm 17,1 +/- 0,4 0,210 980 7809956010
120 4/0 576 x 0,5 2,03 mm 18,6 +/- 0,4 0,164 1210 7809126010
  • Weitere Anfertigungen auf Anfrage