UL 11028

Construction

 

  • Conductor:                TPC - tin plated copper acc. EN 13602
  • Core insulation:          UL-mPPE 105°C
  • printing:                 E 472542 AWM Style 11028 105°C 600V halogen free

 

Technical Data

 

  • Test voltage:             6000 V
  • Operating voltage Uo/U:   600 V
  • Temperature
                              range moved     -10°C to +105°C
                              range static    -40°C to +105°C

 

Properties

 

  • halogen free
  • flame retardant acc. UL 2556/FV-2/VW-1;CSA FT-1

AWG-Number Construction max.mm Core Ø mm max. conductor res. Ω/km Cu-Weight kg/km Total weight kg/km Article number
28 7 x 0,127 0,95 2,2 0,9 1,60 7270280710
26 7 x 0,160 1,04 136,0 1,4 2,16 7270260710
24 7 x 0,203 1,15 87,0 2,1 3,01 7270240710
22 7 x 0,254 1,30 56,0 3,3 4,36 7270220710
20 7 x 0,320 1,52 34,0 5,5 6,80 7270200710
18 19 x 0,254 1,85 19,0 9,6 10,97 7270181910
16 19 x 0,300 2,05 14,0 13,5 14,84 7270161910
  • Weitere Anfertigungen auf Anfrage
  • Alle Angaben ohne Gewähr
  • Sollten Sie Fragen zu diesem Produkt haben, können Sie uns gerne telefonisch oder über unser Kontaktformular erreichen.

Datenblatt herunterladen