UL 11029 AWG 16 - AWG 28

Construction

 

  • Conductor:                TPC - tin plated copper acc. EN 13602
  • Core insulation:          UL-mPPE 105°C
  • Printing:                 E 472542 AWM Sytyle 11029 105°C 1000V halogen-free 

 

Technical Data

 

  • Test voltage:             10000 V AC
  • Operating voltage Uo/U:   1000 V AC
  • Temperature
                              range moved      -25°C to +105°C
                              range static     -40°C to +105°C

 

Properties

 

  • halogen free
  • flame retardant according to UL 1581 VW-1/UL2556 FV-2, CSA FT-1

AWG-Number Construction max.mm Core Ø mm Cu-Weight kg/km Total weight kg/km Article number
28 7 x 0,127 1,05 0,9 1,78 72710280 + colour
26 7 x 0,160 1,15 1,4 2,36 72710260 + colour
24 7 x 0,200 1,30 2,1 3,01 72710240 + colour
22 7 x 0,250 1,45 3,3 4,72 72710220 + colour
20 7 x 0,320 1,65 5,5 7,08 72710200 + colour
20 19 x 0,20 1,65 5,8 7,26 72710201 + colour
18 19 x 0,254 2,00 9,6 11,48 72710180 + colour
16 19 x 0,300 2,23 13,5 15,41 72710160 + colour
  • Weitere Anfertigungen auf Anfrage
  • Alle Angaben ohne Gewähr
  • Sollten Sie Fragen zu diesem Produkt haben, können Sie uns gerne telefonisch oder über unser Kontaktformular erreichen.